The main control protocol is KNX. Panel equipment and keypads from Gira (Germany) were used, along with Ekinex thermostats (Italy).
Technical lighting is dimmed via DALI, integrated into KNX through a gateway.
Roller blind and venetian blind drives are controlled using KNX shutter relay actuators.
Air handling units are controlled via the RS-485 protocol, also integrated into KNX using a gateway.
Air conditioners are integrated into KNX using Zennio KLIC Mitsubishi gateways.
In addition, a separate power supply design and load calculations were completed.
The project documentation includes floor plans, control and multimedia block diagrams, wiring diagrams, a single-line electrical diagram, panelboard and 19” rack layout drawings, a Wi-Fi coverage heatmap, a cable schedule, and a bill of materials.
Structured cabling system (SCS) design, including external surveillance
Backup power supply for the video surveillance system and automation equipment
Wi-Fi coverage calculation
13-zone multiroom audio system with AirPlay content playback